HDTi-6000 Heart Valve Pulse Duplicator Test System

HDTi-6000 Heart Valve Pulse Duplicator Test System

Цену уточняйте

  • В наличии
HDTi-6000 Heart Valve Pulse Duplicator Test System
HDTi-6000 Heart Valve Pulse Duplicator Test SystemВ наличии
Цену уточняйте
+375333225712
Павел
  • +375333224183
    Денис
  • +375172353957
    Тел./факс
  • +375297662145
    Галина
  • +375296297425
    Светлана
+375333225712
Павел
  • +375333224183
    Денис
  • +375172353957
    Тел./факс
  • +375297662145
    Галина
  • +375296297425
    Светлана
  • График работы
  • Адрес и контакты

In a revolutionary fashion, BDC Laboratories’ HDTi-6000 heart valve pulse duplicator achieves ISO 5840 performance assessment in a focused and efficient manner similar to our established HDT-500 system, with the added capability of integrated high speed video to facilitate real-time visualization of the heart valve under test. The HDTi-6000 can accommodate up to 5 high speed cameras, all simultaneously documenting multiple test article views with concurrent pressure and flow waveforms. After each heart valve test run, a variety of both waveform analyses and image analyses are available to characterize the heart valve’s performance and leaflet kinematics. Included with the many unique system features is the ability to playback video while synchronized to the pressure and flow waveforms to assess the heart valve leaflets at any particular point in the cardiac cycle.

The HDTi-6000 pulse duplicator can accommodate both surgically implanted and transcatheter valves while being configured as either as a left heart simulator or right heart simulator. Utilizing a novel linear clamp assembly with no need to drain the system between samples, the HDTi facilitates exchange of the test article in minutes and significantly increases productivity. BDC’s proven PD-1100 pulsatile pump is the fluid driving source for the HDTi-6000 pulse duplicator system yielding high repeatability, reproducibility and dynamic configurability.

The accompanying Statys® HDTi control and monitoring software gives the user absolute control over the pulse duplicator excitation waveform, while seamlessly integrated all cameras for both live and post-test video review. The real-time data collection and analysis tools embedded in the software provide instantaneous measurement the device parameters, such as pressure drop, effective orifice area, regurgitant volumes, and leakage rates.

 

Specifications & Benefits

 

Integrated High Speed Video (Optional):

   ·      High resolution high speed cameras integrated into the test system eliminate the need for secondary video systems

   ·      With up to 5 cameras, the heart valve under test can be complete assessed and documented from all angles

   ·      Integrated video playback with synchronized pressure and flow waveforms provide the ultimate platform for investigation and analysis

Linear Clamp Operation:

   ·      A captured acrylic fixture secures the heart valve test article to facilitate quick exchange and ease-of use

   ·      Changing of the heart valve test article can occur without the need to drain the system fluid

Heart Valve Type: Aortic, Mitral, Pulmonary, or Tricuspid

Heart Valve Size: Up to 95 mm (standard)

Flow Rate: 0-10 L/min

Driving Waveform: Sinusoidal, Arbitrary

Frequency: 2-240 bpm

Test Fluid: Water, Saline, PBS Solution, Blood Analog

Temperature: up to 50 °C

Flow Monitoring: Ultrasonic Technology

Regulatory Compliance: Complies with ISO 5840, and all applicable European Union directives and standards for safety and EMC. CE Marked.

            

Statys HDTi Software

 

·                Integrated data collection and analysis tools to determine all required ISO 5840 and FDA test parameters either real-time or through post processing

·                Integrated video playback with synchronized pressure and flow waveforms provide the ultimate platform for investigation and analysis

·                Real-time separation of the continual waveforms into individual beats ease data review

·                Sinusoidal or arbitrary waveform driver excitation accurately simulates clinical performance

·                Beat analysis reduced data is summarized and output in excel format to quick processing

·                Auto-generated reports with all relevant data for efficient documentation of each test

·                All temporal signals can be output and saved in high-fidelity for post-test waveform analysis

·                User-focused software environment to facilitate ease of system operation

 

Accessories

 

·                High Speed Cameras: The HDTi-6000 can accommodate up to 5 high speed cameras with 1280×1024 resolution. The cameras can be oriented for inflow, outflow and each of the 3 leaflet aspects.

·                Flow Meter with Probe: Customized ultrasonic flow meter with probe gives precise, temporal volume flow measurement.

·                Automated Image Analyses: In addition to manual measurements from acquired video, the automated image analysis package provides means to determine key attributes automatically through software algorithms.

·                Calibration Reference: Custom designed calibration reference of all camera to convert pixels to physical dimensions (e.g. millimeters).

·                Adjustable Lighting Source: Optimal system adjustable LED lighting system that includes either ring or panel lights to optimal video imaging.

·                Heating Circulation Valve: System valve to utilize at a test article to facilitate heating during initiation of test system.

Drip Tray: Test system drip tray designed to integrated with the test apparatus and capture all fluid leaks.